Getting error code-200429 when executing a DAQmx Read

Hello again all.  I'm once again up against an error in a seemingly simple part of my code.  I'm using a USB-6009 multifunction I/O module.  I am currnetly controlling two Mass Flow Controllers with analog out 0 and 1 (device 1).  I'm also using analog in 0 and 1 to read the indicated voltages back from those MFCs.  I have recently tried to add a third analog in (first ai2, and then ai3) to read the analog signal coming in from an Alcatel Helium Leak Detector.  Every time I run the vi, I get an error message (200429, pointing to the DAQmx Read function.  The indicator for the Alcatel voltage reads 0.00.  Can anyone suggest some solutions?
0 Kudos
Message 1 of 3
(2,878 Views)

hi there

you can't use a VISA task after it has been closed (see attachment)

 

Best regards
chris

CL(A)Dly bending G-Force with LabVIEW

famous last words: "oh my god, it is full of stars!"
Message 2 of 3
(2,866 Views)
Never Mind...I got it.  I had to go into my sub vi where I initialy created the DAQ channel, and add another channel to it.  It seems a little frustrating that you must create all of them simultaneously, rather than add them as you go.  Anyway, it works great now.  I just input dev1/ai0:2, and I'm up and running!  Thanks anyway.