How to measure the pulse duration of a TTL signal using AI?

Yes there is never enough counters and I have asked NI why the counters are limited to 2 when many applications require more than two.  I have used the 6602 card which is a pure counter card it is about $600 and has 8 counters.  it is a great little piece of hardware and I highly suggest it for counter applications requiring scalable channels.  I would hope that Ni would consider a multifunction card which is geared towards counting but provide a few analog functionalities such as 6 counters, 8 AI 2 AO conficuration but nothing is available yet.
 
Paul
Paul Falkenstein
Coleman Technologies Inc.
CLA, CPI, AIA-Vision
Labview 4.0- 2013, RT, Vision, FPGA
0 Kudos
Message 11 of 12
(900 Views)

Hi Paul,

You are extremely right boy. However, there's nothing much we can do about it at this moment.

Anyway, thanks for your advices. I just got to dig in to figure out how i can measure

that TTL signal's pulse width using AI.

Cheers!

0 Kudos
Message 12 of 12
(896 Views)