How to solve this??

Solved!
Go to solution

Kindly find the attachment and let me know how to solve it ...

 

Thank you!!

 

Rashme SR

0 Kudos
Message 1 of 6
(3,841 Views)

1.  Code it in LabVIEW and try it out.

2.  Carefully think about it and work it out step by step as to what LabVIEW would do.

 

 

0 Kudos
Message 2 of 6
(3,834 Views)

I tried it in Labview. I dont get any output. I am attaching the vi for your reference.

 

Rashme SR

0 Kudos
Message 3 of 6
(3,820 Views)
Solution
Accepted by topic author Rashme_SR

While implementing, Right click on feedback node and use option ‘Move initializer one loop out’ then you can see initializer terminal on for loop.

 

-
Amit
CLAD
Message 4 of 6
(3,817 Views)

see the attached VI

-
Amit
CLAD
0 Kudos
Message 5 of 6
(3,815 Views)

Thank you so much!!