02-25-2020 06:21 AM - edited 02-25-2020 06:24 AM
This is one of the best diagram and explanation (Bob_Schor) that I have used so far from the community resources. THANK YOU very much! Can I post how I use it for my data recording, just to have a feedback from you if this is the best option for what I want to do?
Many thanks, beautiful vi resource and explanation!
02-27-2020 01:23 AM
Hey,
Please find the attached VI .
I have timed the case structure by modifying the VI that you had attached. Here, I have used a timestamp along with shift registers to time the case structure .The timing turns out to be in and around 17 seconds and this is being displayed every cycle ( cycle here refers to opening and closing of the mould).
02-27-2020 02:38 AM
Thank you very much for your kind answer. Please, can you send me a picture of the diagram, I can not open the vi (I have LabVIEW 17).
Kind regards!
02-27-2020 03:39 AM - edited 02-27-2020 03:45 AM
Hey,
Please find the attached snapshots.
02-27-2020 05:42 AM
Thank you very much!!!