08-31-2005 12:25 PM
09-01-2005 05:50 PM
09-02-2005 08:12 AM
Hi Jesse,
thanks for the response!
The camera is actually a MicroPix 640 which was bought via CCDDirect. The following shutterSpeed attributes appear in MAX: manual(relative) 2-533, manual(absolute) 0-0.13, auto, and ignore. I downloaded the technical reference manual from the manufacturer and it seems that there are a bunch of other registers that dont appear in MAX. These registers have a 1394 base address (FFFF F000 0000h) and base offset (FFFF F0F0 0000h) I havent seen a specific comment regarding "extended" shutter mode, but will keep looking.
thanks,
Ronen
09-07-2005 01:20 PM
09-14-2005 02:04 PM
09-16-2005 02:09 PM
Hello Ronen,
I looked around for an example, but I was not able to find one for LabVIEW. It seems unlikely that an example program exists, since each camera could have a different set of registers (those not part of the DCAM spec). The manual has a couple usage examples on page A-3. The Basic Example should work for all DCAM cameras, but the Advanced Example is specific to the registers on the Basler A601f.
Best Regards,
Jesse D.
Applications Engineering
National Instruments