09-10-2009 02:11 AM
09-10-2009 07:59 AM
If you are using the scale to engineering units VI on the data from the DAQmx task, then your data is originally represented in mm/s^2 and pa. The Sound and Vibration integration functions manages the units and converts them with the appropriate math the displacement or decibels. The units output of the integration VI will confirm the VI has done the work. There should be not extra mathematics, just run the waveforms thru the scale to engineering units VI and then the integration VI.