09-14-2007 08:20 AM
09-17-2007 06:35 PM
09-18-2007 12:30 PM
The crash log is attached.
The attached sZLS ECG6 simplified.vi communicates over RS232 with ECG monitoring hardware. There are 3 tab views in the main VI, which by default displays the Heartrate tab upon startup. The crash seems to happen when attempting to view the ECG Chart tab. The ecgeProcessPackets.vi subVI is also attached - this is where the original ECG Chart ouput resides.
Also, I recently updated to LV 8.5 and I was able to run this VI in both LV 8.2 and LV 8.0 several times without any crashes.
09-18-2007 01:34 PM
09-19-2007 05:32 PM
10-04-2007 01:09 PM
Yes, while the program is running and consistently it seems to happen shortly after selecting the "ECG Chart" tab, I get the Microsoft error message (Error1.png attached) and after acknowledging the error Labview goes bye bye.
Upon restarting Labview I get the "previous internal error" message (Error2.png attached) and the error log file is generated (lvlog10-04-07-13-48-17.txt attached).
I don't know if it will help since you probably can't run the VI's without the ECG monitoring hardware (a device manufactured by Active Corp. communicating with my PC serially via a COM port), but I will go ahead and attach all of the related subVI's in the ensuing post.
msavina
10-04-2007 01:14 PM
10-05-2007 03:40 PM
02-20-2008 07:00 AM
02-21-2008 03:32 PM