10-30-2006 08:14 AM
10-30-2006 08:59 AM
Hello,
I had some problems when setting up NiDaq 8.3. My MAX 4.1 couldn’t log its data base.
I use fsecure software as firewall and this is how I did to have good
work with MAX.
After installation of nidaq 8.3 I had to configure manually the acces control
of fsecure:
I am using a French version of fsecure and this is a translation of what I did (I hope it’s the same thing for other langage)
Open Fsecure, clic on « internet » and « configure »
Then clic « Add »
Browse C:\Program Files\National Instruments\MAX\NIMax.exe.
And allow all application and ports for this software
Make the
same thing for:
C:\Program Files\National Instruments\MAX\nimxs.exe
C:\Program Files\National Instruments\MAX\NiAsstnt.exe
C:\Windows\systeme32\nipalsm.exe
C:\Program Files\National Instruments\Ni-DAQ\HWConfig\nidevmon.exe
After repair Nidaq 8.3 and restart windows.
Normally it works.