LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

NI-USB-6002 / 1-10 GHz frequency and Labview

Hello, 

 

I am looking to purchase Labview to do some signal processing, measurements, monitoring and control. I am working with 1-10 Ghz RF recorder and NI-USB-6002.

Which Labview version will support this?

 

Thanks

0 Kudos
Message 1 of 3
(1,110 Views)

Just to clarify, LabVIEW is a programming language, in order to use an instrument you need the respective driver to use in the programming language.

 

For the USB-6002, it uses the DAQmx driver and any version of LabVIEW in the past decade with the appropriate DAQmx version will work.

 

As for your "1-10GHz RF Recorder", it is still unclear of the manufacturer, model, driver availability etc.,

Santhosh
Soliton Technologies

New to the forum? Please read community guidelines and how to ask smart questions

Only two ways to appreciate someone who spent their free time to reply/answer your question - give them Kudos or mark their reply as the answer/solution.

Finding it hard to source NI hardware? Try NI Trading Post
0 Kudos
Message 2 of 3
(1,081 Views)

USB-6002 and 1 - 10 GHz RF!!!!!!

 

That sounds not only like an oxymoron but like a clash of a black hole and a space ship. Only one of them will notice anything in the process. 😀

 

Unless you have some really serious high end hardware in between that does some frequency downconverting and signal conversion before you get some (almost) static analog signal, the USB-6002 will basically see simply nothing of your RF signal.

 

If you talked about the NI USRP devices instead, there would be some chance, but they stop at 6GHz input frequency.

 

The really important question here is what sort of intermediate hardware you use (supposedly your RF recorder). Use of the USB-6002 in combination with it may simply be a misunderstanding from your side and you would be better of to communicate directly with the RF recorder but how exactly that can be done would depend a lot on the make and model of said recorder.

 

As far as the USB-6002 is concerned, EVERY LabVIEW version since at least about 15 years will support use of it.

Rolf Kalbermatter  My Blog
DEMO, Electronic and Mechanical Support department, room 36.LB00.390
0 Kudos
Message 3 of 3
(1,049 Views)