LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

NIVISATulipPassport.msi copy to Exe error

I recently reinstalled Labview 2016 to my Windows 10 laptop. While attempting to rebuild one of my applications that worked prior to reinstall, I received the error detailed below.

'C:\Program Files (x86)\National Instruments\Shared\MDF\Manifests\NI-VISA Tulip Passport {326C5DFC-D2BE-4CB4-B9EB-E55696D74837}.xml' Exists.

 

Tulip is available in NI MAX under passports and is enabled. I changed the build output directory, thinking this was a permissions error, and ran Labivew as admin but that did not resolve the error.

 

The only issue I can find that is similar to me is this one here, however Tulip passport is available in MAX so this doesn't seem to apply to me.

 


The following errors and warnings were recorded during the build:

Error:
An internal Windows function returned an error.
Code:
-12

Error:
An internal tool or library returned an error.
Details:
Error Messages
Could not copy file NIVISATulipPassport.msi to output path Installer\Volume\bin\p7 for part 'NIVISATulipPassport.msi' in product 'C:\Program Files (x86)\National Instruments\Shared\MDF\Manifests\NI-VISA Tulip Passport {326C5DFC-D2BE-4CB4-B9EB-E55696D74837}.xml'. Error Code: -12

Code:
-21

Using Labview 2022, Windows 10
0 Kudos
Message 1 of 2
(1,117 Views)

Resolution:

I had installed additional Labview packages with different activation information and it screwed up my whole installation.

 

Using Labview 2022, Windows 10
0 Kudos
Message 2 of 2
(1,050 Views)