03-18-2018 03:22 PM
I was doing a short project the other day in NXG to get a little practice and was going to use the In Place Element Structure. I'm using NXG 2.0 (installed it just a week ago) and when I went to use the in place element structure I could not find it. I tried quick drop and help. According to this link, http://www.ni.com/documentation/en/labview/latest/node-ref/in-place-element-structure/ , it looks like it should be in there. I'm wondering if I'm missing something. I've included a picture of what my Program Flow menu looks like. I appreciate any help.
Erich
Solved! Go to Solution.
03-19-2018 08:11 AM
Looking at the palette file, it looks like this element is not included in the licenses for any currently existing NXG 2.0 products (It's licensed for LabVIEW Communications which was not included in the initial 2.0 release).
I don't have much other information, but I forwarded this info to the people responsible for that page to let them know this element isn't currently in 2.0. Hope this helps!
03-19-2018 08:19 AM
I was suspecting that was the case, or something like it and didn't want it to confuse anybody else if it wasn't included. Thank you for your response.
Erich