Need to find In Port and Out Port vis.

Hi all.

I have some software running on old hardware that uses In Port.vi and Out Port.vi and I need to modernise it. I can't run it because it doesn't find these sub vis when loading. Is there anywhere I can find them? I don't have any very old versions on my machine any more. Thanks

0 Kudos
Message 1 of 7
(3,186 Views)

They don't exist anymore.  And if they did, I don't think they'd work because modern operating systems won't allow you to have the direct control of a hardware port that those VI's did.

0 Kudos
Message 2 of 7
(3,183 Views)

Thanks. I don't need them to work, I just need the vi to run so I can change some of the other sections of code and I can't get it to run if it doesn't load them.

0 Kudos
Message 3 of 7
(3,180 Views)

Hi ASH,

 

create two dummy VIs with the same name and connector pattern!

(In LV2011 and in LV2017 I still find that portaccess.llb in vi.lib\Platform…)

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 4 of 7
(3,178 Views)

Slap a diagram disable around them 


"Should be" isn't "Is" -Jay
0 Kudos
Message 5 of 7
(3,152 Views)

@GerdW wrote:

Hi ASH,

 

create two dummy VIs with the same name and connector pattern!

(In LV2011 and in LV2017 I still find that portaccess.llb in vi.lib\Platform…)


D'oh! why didn't I think of that! Thanks.

0 Kudos
Message 6 of 7
(3,147 Views)

@JÞB wrote:

Slap a diagram disable around them 


I did try that but it still wouldn't run.

0 Kudos
Message 7 of 7
(3,144 Views)