Numerical integration error

Solved!
Go to solution

I am trying to compute the integral of 3x^2 in the range 0-1 with step 0.01 using the Numerical integration VI. I am getting a data mismatch error with the array output when I connect it to the VI. Why is that so? Thanks. 

0 Kudos
Message 1 of 4
(3,063 Views)

your vi is in labview 2018, try to upload if any lower version vi.

i can't able to open your vi.

 

Please Refer to the 1D Explorer VI in the labview\examples\Mathematics\Optimization directory for an example of using the Integration VI.

I think this can solve your problem....

 
 
0 Kudos
Message 2 of 4
(3,049 Views)
Solution
Accepted by topic author dbhadra

Remove the "built array" after the FOR loop. (The auto-indexing output tunnels already makes you an array).

 

Maybe do a few tutorials first?

0 Kudos
Message 3 of 4
(3,041 Views)

thanks for the solution