01-17-2025 12:15 PM
Hi.
I'm trying to use a legacy PCI-6070E (PCI-MIO-16E-1) board in LabVIEW, however, It do not appears at DAQ Assistant Wizard, as shown by the image attached. Please, help me to setup this board. I've readed a lot of posts here, especially about software and hardware compatibility, but still without resolution.
What I've already tried:
Operating System(OS) Windows 10 Professional
OS Version 10.00.19045
OS Info
Processor Intel(R) Core(TM)2 Duo CPU E4500 @ 2.20GHz / Intel64 Family 6 Model 15 Stepping 13 / GenuineIntel / 2211 MHz
Number of Processors 2
Physical Memory 2.99 GB of RAM
Drive C:\ 385 GB of 464 GB free
NI Software: Version:
CVI Runtime 19.0.0.49154
NI-DAQmx Device Driver 20.7.0f155
NI-DAQmx ADE Support 20.7.0
NI-DAQmx MAX Configuration 20.7.0
NI I/O Trace 20.5.0f0
LabVIEW 2020 SP1 (64-bit) 20.0.1
Database Connectivity Toolkit 20.0.0
Report Generation Toolkit For Microsoft Office 20.0.0
LabVIEW Runtime 2018 SP1 f5 18.0.1
LabVIEW Runtime 2020 SP1 (64-bit) 20.0.1
Measurement & Automation Explorer 20.5.0f0
Measurement Studio Visual Studio 2012 Support - See individual versions below.
NI PXI Platform Services Configuration 20.7.0f230
NI PXI Platform Services Runtime 20.7.0f230
NI-PAL Software 20.0.0
NI System Configuration 20.5.0f0
LabVIEW Runtime 2019 SP1 f3 19.0.1
LabVIEW Runtime 2020 SP1 20.0.1
Solved! Go to Solution.
01-17-2025 02:08 PM
PCI-6070E is so legacy that no recent OS, driver, or LabVIEW will support it.
01-17-2025 03:53 PM
Devices and Modules No Longer Supported in NI-DAQmx
NI-6070E was last supported in NI-DAQmx 19.0
You would need to uninstall and reinstall LV2019 and NI-DAQmx 19.0
01-17-2025 04:38 PM
@ZYOng wrote:
Devices and Modules No Longer Supported in NI-DAQmx
NI-6070E was last supported in NI-DAQmx 19.0You would need to uninstall and reinstall LV2019 and NI-DAQmx 19.0
Thanks ZYOng. I stand corrected; indeed it is supported in DAQmx 19.0
01-28-2025 04:01 AM
Thanks, ZYong!
This LabView and DAQmx works with that legacy board! 👍