Hi ssk,

Do you have multiple .res files in your labview\PDA\Utilities\LVPocketPCProject\Rsc directory?

Error CVT1100 indicates duplicate entries in the resource file(s). Did you by any chance back up the original resource file in the same directory, but not change the file's extension?

If yes, you might end up with two .res files with similar resource entries. Try changing the backup file extension, maybe to a ".original".

Let me know if this does not solve your problem.

Regards,
miko
0 Kudos
Message 11 of 12
(1,001 Views)
Thank miko, that has solved it!!

I had backup up my original file in the same folder (called it backupStringList.res).

To NI - it would be worth putting a note on the following link to inform people not to do this in the future:

http://digital.ni.com/public.nsf/allkb/AA87B627C42616C48625711A0063FFAF

Thanks

ssk