 yangmie
		
			yangmie
		
		
		
		
		
		
		
		
	
			
			
    
	
		
		
		05-14-2019
	
		
		09:36 PM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 - last edited on 
    
	
		
		
		10-17-2025
	
		
		09:28 PM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 by 
				
		 Content Cleaner
		
			Content Cleaner
		
		
		
		
		
		
		
		
	
			
		
First, please open the following web.
https://knowledge.ni.com/KnowledgeArticleDetails?id=kA03q000000x3IVCAY&l=en-US.
When I went to step 4 based on this post,I met a question.
I did not find the Oscillator and  PXI_Clk10 in the source.I also did not find the ClkOut and  BoardClk in the Destination.
Thank you very much.
05-16-2019 03:41 AM
Hi,
Did you complete the step below?
Single-Board Disciplining with the PXI-6683H: Since the PXI-6683H is a hybrid card and does not fit in the timing slot of the chassis, it cannot override the chassis’ backplane directly. Instead, you will need to externally cable the disciplined on-board oscillator of the PXI-6683H to the 10 MHz Ref In connector on the chassis. (Consult your chassis’ user manual to ensure your chassis has a 10 MHz Ref In). To do this, complete the following steps:
 BiffStudley
		
			BiffStudley
		
		
		
		
		
		
		
		
	
			07-27-2023 01:54 PM
That doesn't fix it.
 TylerK
		
			TylerK
		
		
		
		
		
		
		
		
	
			
			
    
	
		
		
		07-28-2023
	
		
		10:18 AM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 - last edited on 
    
	
		
		
		10-17-2025
	
		
		09:30 PM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 by 
				
		 Content Cleaner
		
			Content Cleaner
		
		
		
		
		
		
		
		
	
			
		
Hi,
The NI-sync API has two similar name VIs.
The article is using the former. So, you might want to check that.
Regards,
-Tyler
 BiffStudley
		
			BiffStudley
		
		
		
		
		
		
		
		
	
			08-01-2023 04:12 PM
I guess I'm misunderstood. I don't have access to Labview. How do you get the Oscillator and CLKOUT to show up in the NIMAX test panels.