06-04-2009 09:01 AM - edited 06-04-2009 09:05 AM
Hi!
Have the system where countinously measuring same poins over and over again. These points are in X-axis and measuring result on Y-axis. I have tagged two different solutions what I have tried. 1, where is buffer (founded on example) and 2, where is used arrays and shift register.
Problems:
solution 1. When coming back from point 10 to 0, plot drows that return.
solution 2. Arrays now initialized to 0 and no history. But if no initializing at all, history is endless.
Have any other solutions to do this?
-Thx, again-
Solved! Go to Solution.
06-05-2009 01:29 PM
06-08-2009 01:45 AM
06-08-2009 06:54 AM
11-19-2009 12:35 AM
aeastat can u please post the vi in 8.5 labview.... I have kind of similar problem..where, I'm acquiring torque and speed data with DAQ and then i want to plot torque v/s speed...
thanks..
11-19-2009 06:59 AM - edited 11-19-2009 07:00 AM