10-26-2005 03:09 AM
Hello,
I am using a pressure sensor that needs 5V supply and generates a 0->2.5V output. I would like to read this voltage using Labview. However I am not sure which mode( diff, RSE, or NRSE) I should use here. I have attached a very simple photo of the way to connecte the sensor ( delivered with the sensor). There is : 1 supply connexion
1 Ground connexion
1 AGround connexion
1 Vout connexion
I have already tried :
RSE mode : connecting to ACH and AIGND. I see a 1 to 2mV offset ( compared to a LEM). But I thought this wasn't appropriate in my situation?
NRSE mode : connecting ACH and AISense. Offset <1.5mV
( I haven't tried with any resistance )
Since the way of connecting this sensor is very common ( I will probably use this way of connecting again), could anybody tell me what the correct mode is? I have already read answers on the forum and the NI application note about how to use those different modes, but I haven't been able to conclude....
Any kind of help would be great!
Thanks,
Toto
10-28-2005 04:28 AM
Bonjour,
Le problème d'offset peut-être lié à plusieurs paramètres qu'il faut chercher à isoler.
Quelle est la différence entre le GND et le AGND sur votre capteur? Comment alimentez-vous ce capteur, via le +5V de la carte d'acquisition? Comment calculez-vous cet offset? Avez-vous essayé de connecter des résistances de biais sur les entrées de la carte?
La note d'application suivante récapitule bier les différents modes de connectique.
Cordialement,
DD
http://zone.ni.com/devzone/conceptd.nsf/webmain/177A8B29FEDC0F5886256FA90083C0F8
11-02-2005 01:23 AM