LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

SHOLD I USE ALL THE HANDSHKING SIGNALS WHEN USING VISA READ AND WRITE?

I want to send string from com3 to com 4 using the example 'Basic 2 port serial write and read.vi'.How should I connect my com3 and com4 which are available on my pc.? Do I need to connect all the handshaking connections?

0 Kudos
Message 1 of 3
(2,538 Views)

I think it is not required to connect hand shaking signal.

You need to used crossed serial cable for the communication.

 

Regards

Prabhakant

 

https://decibel.ni.com/content/docs/DOC-16283

 

https://decibel.ni.com/content/docs/DOC-16642

Regards
Prabhakant Patil
0 Kudos
Message 2 of 3
(2,536 Views)

In general, no.  There are some instruments that might require it, but between two COM ports on your computer you don't have to worry about it.  As said, just connect the TX of one port to the RX of the other and visa versa.  It also wouldn't hurt to connect the grounds.


GCentral
There are only two ways to tell somebody thanks: Kudos and Marked Solutions
Unofficial Forum Rules and Guidelines
"Not that we are sufficient in ourselves to claim anything as coming from us, but our sufficiency is from God" - 2 Corinthians 3:5
Message 3 of 3
(2,516 Views)