Send joystick axis and button information to Myrio via NI-Visa

Solved!
Go to solution
RavensFan Thanks for clearing up the mess. The wait is 70 milliseconds, but it takes a second to shut down, I think this is my programming error. Because if I close the program in Myrio or any running program on the computer, the other one closes a little later.
0 Kudos
Message 11 of 12
(579 Views)
Solution
Accepted by topic author constructionworker

Thank you for every idea. I solved my problem using the Timed while loop. The code fragment is in the appendix below.

 