07-13-2009 12:14 PM
07-13-2009 12:25 PM
07-13-2009 12:29 PM - edited 07-13-2009 12:30 PM
Also, I would suggest wiring up your error terminals just to make sure your not getting any read errors.
You could change your string indicator from "normal display" to "hex display". Knowing what the extra character(s) are in hexadecimal might help you debug the problem (i.e. -- is the extra charater white space, CR/LF, etc?)
07-13-2009 12:38 PM
You didn't wire any of the terminals of the "VISA Configure Serial Port.vi" so I expect your defice to be set up as the default values of that VI. Is it really so?
Adding a small delay in your while loop won't hurt anyone too
07-13-2009 12:40 PM
07-13-2009 12:45 PM