05-02-2007 08:10 AM
05-02-2007 10:28 AM - edited 05-02-2007 10:28 AM
It's milliseconds. You can see this for yourself by just opening the front panel of the function. You'll see the label of 'timeout (10sec)' and a value of 10000 in the control.
Message Edited by Dennis Knutson on 05-02-2007 09:29 AM
05-03-2007 08:25 AM
Dennis is right, the unit is ms !
But I agree that the label is misleading and that the help for VISA Configure Serial Port.vi is not clear enough. Besides, you're not the first who rises up this question.
My suggestion : submit a feedback on the help for this VI to NI by clicking on the link in the bottom of the help. Chances are good that the text will be changed in a next version of LV.