LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Traditional NI-DAQ support for LabVIEW 8.5?

I have an application where I need to use Traditional NI-DAQ (I have a PCMCIA DAQCard), and I just recently upgraded to LabVIEW 8.5. After installing LabVIEW 8.5, Traditional NI-DAQ 7.4.4, and NI Device Drivers Aug 2007, the "Measurement I/O" tab in LabVIEW contains support for NI-DAQmx (which I can't use with my DAQ device), but not for Traditional NI-DAQ (which I need).

Since the Traditional NI-DAQ drivers were released in March and LabVIEW 8.5 was released this month, I'm assuming that there are no existing Traditional NI-DAQ drivers for LabVIEW 8.5 yet. Is National Instruments planning to support Traditional NI-DAQ in LabVIEW 8.5, and if so, when are these drivers planned to release?

- Alex K.
0 Kudos
Message 1 of 2
(2,729 Views)
Nevermind, the problem was solved by uninstalling and reinstalling Traditional NI-DAQ-- apparently Traditional NI-DAQ only attaches itself to the latest version of LV at install, which wasn't 8.5 at the time of installation.