‎03-29-2016 07:48 AM
‎03-29-2016 08:04 AM
I don't see why not, as long as you have the latest version of the toolkits listed.
‎03-29-2016 08:06 AM
Do you complete the installation instructions?
‎03-29-2016 08:23 AM
I'm using LabView 2015 Professional Developement System and have the Advanced Signal Processing Toolkit 2015 (which includs the System Identification Toolkit) as well as the Sound and Vibration Measurement Suite 2015. But when I try to use the MP_FDPI.vi I always get the error that some VIs couldn't be found. The names of the VIs are:
si_chebychev matrix.vi
si_Estimate Model_input FRF format adjustment (SISO).vi
Are the VIs renamed in LV 2015 or something like that?
‎03-30-2016 03:13 AM
Hey SchmiMich,
I have tested the VIs with LabVIEW 2015 32-Bit english and everything works like expected.
I have installed the Advanced Signal Processing Toolkit 2015 which contains now the System Identification Toolkit and the Sound and Vibration Measurement Suite 2015. With this Toolkits installed, I can execute the Vi without missing dependencies.
I'm not able to find a VI wich is named "si_chebychev matrix.vi". It seems not to be part of the Toolkit, because I would not be able to run the VI without the VI on my hard disk.
The VI "si_Estimate Model_input FRF format adjustment (SISO).vi" is located here
C:\Programme\National Instruments\LabVIEW 2015\vi.lib\addons\System Identification\Frequency Domain Estimation Subs.llb\si_Estimate Model_input FRF format adjustment (SISO).vi
It looks like you don't install all the component, which are neccessary to run the VIs. This is not a Version related issue.
Ragards, Stephan