VAS and VDM 2009 application on LV2013

Hi,

I've been having issues running a multiple camera VI written in LV2009 to run in 2013. It is an executible. Specifically, the tools to take line-out and guassian fits don't work.  I have 2009 and 2013 installed and 2009 VAS and VDM installed as well as the 2009 run time engine.  Previously I had it working on in a similarly configured computer with no problems.  Short of removing and reinstalling Labview, does anybody have an idea of what may be missing?  Thanks.

0 Kudos
Message 1 of 5
(3,060 Views)

Hi Spinks,

 

If you have your application created into an executable, it will run through the 2009 Run Time Engine instead of through LabVIEW 2013. Did it work before you installed 2013?

Thomas N.
Applications Engineer
National Instruments
0 Kudos
Message 2 of 5
(3,000 Views)

Thank you for the response.

 

Yes, it did work before installing LV2013, and currently works on several machines running LV 2013.  I've installed the run time engine for 2009 and VAS and VDM from 2009 as well... like the other machines.  I suspect something is missing or currupted, but haven't been able to figure out what it could be.  Most of the program works well, except for the analysis portion of the software.  becasue of that I suspect there is some package in image anaylsis is not being found, but they all look like they are there.  I'm thinking it would be best to just reinstall LV.  😞

 

Thanks again

0 Kudos
Message 3 of 5
(2,951 Views)

Sounds like a reinstall should do the trick. Let me know if that doesn't fix the problem.

Thomas N.
Applications Engineer
National Instruments
0 Kudos
Message 4 of 5
(2,929 Views)

Thanks, it fixed it.

 

0 Kudos
Message 5 of 5
(2,920 Views)