11-08-2013 03:42 AM
Hello,
Iam sorry for my beginers question, but we worked with program created in labview 7 and now we upgrated on labview 2011. Unfortunately there is problem with conection between two elements. Is some simple
adjustment or change something? Problem is on output from camera and work with image probably in LB 2011 is it different. When i start the program it show some errors }on picture]
For any advice will be gratefull
11-08-2013 06:16 AM
I'm pretty sure that IMAQ had a change to its API somewhere since LabVIEW 7. You will need to go through and fix the issues manually.
11-11-2013 12:18 AM
Thank you crossrulz, I agree, but i am not sure how 😞 My idea was some type of convertor between 2 types of image signal. In version LV 7 i see only one. Its old program and I dont have technical support for it, so i trying figure out myself. But it will not be easy how i thought...
11-13-2013
05:32 AM
- last edited on
10-14-2025
11:04 AM
by
Content Cleaner
Dear Pepec!
As You can see on the compatibility chart, the Vision Development Module that was compatible with LV 7 was the version 7.
The oldest version of Vision Dev. Module, that is compatible with LabVIEW 2011 is the 2011 version.
A potential solution could be to use the compatibility library. This can ensure, that Your old VIS will wok also with new LV and Vision module.
I think it is worth to try: http://digital.ni.com/public.nsf/allkb/FD4C0732A20B04B98625775F004F62DF?OpenDocument
Plese let me know, if it helped.
BR,