LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Valid values for OS in conditional disable structure

I have tried to dig through the LV help,  but to no avail.

Where can I find an overview of the valid values for the OS symbol in the conditional disbale structure configuration?
Regards,
André (CLA, CLED)
Message 1 of 7
(3,211 Views)
Hi andré,
these are the possible values: Windows, FPGA, Embedded, RT, Mac, Unix and PocketPC!
You can find this list in the help. Right click on the structure and select "edit conditional structure" and then help.
 
Mike
 


Message Edited by MikeS81 on 05-27-2008 02:10 PM
Message 2 of 7
(3,210 Views)
Hi Mike,

I didn't mean the values for "TARGET_TYPE", but the ones for "OS".

I found this in the help, but it wasn't my question.
"Valid values for the TARGET_TYPE symbol include Windows, FPGA, Embedded, RT, Mac, Unix, and PocketPC."
Regards,
André (CLA, CLED)
0 Kudos
Message 3 of 7
(3,201 Views)
I'm just guessing that they would be the same as the application property App.TargetOS.
Message 4 of 7
(3,194 Views)
That's the point, I too can guess what they might be. App.TargetOS, OS.Name or different?
Regards,
André (CLA, CLED)
0 Kudos
Message 5 of 7
(3,188 Views)

Hello Andre,

I have checked this. The valid value's are:

"Win", "Mac", "Linux", and ""

Also for the next version of LabVIEW the documentation will be inplace for this item aswell as the CPU item.

Regards,

RikP - National Instruments Applications Engineering

Rik Prins, CLA, CLED
Software Development Engineer
Message 6 of 7
(3,152 Views)
smileyhappy ( for those that don't display smileys)



Message Edited by andre.buurman@carya on 06-02-2008 12:33 PM
Regards,
André (CLA, CLED)
0 Kudos
Message 7 of 7