LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Visa Set Properties error on PDA

Hi, I am using a bluetooth DAQ card to acquire data and write it to a PDA application.

 

I have written the code in labview and have run it succesfully on my laptop. I am using the VISA VI's and virtual serial port to communicate with my bluetooth device.

 

The outgoing PORT number on the PDA for the device is 8 so I have fed this into the open visa connection VI. See attached jpg.

 

When I try to run the application on the PDA, I get an error : Code -1073807343 and message Visa set properties.


Can anyone help?

 

Thanks

0 Kudos
Message 1 of 6
(3,250 Views)

What version of LabVIEW PDA are you using? Did you install support for NI-VISA on the PDA?

 

Try using ASRL1::INSTR as the VISA Resource Name for COM port 1.Alternatively, you might be able to use the VISA Find Resource VI to search and retrieve a specific resource or all available VISA resources.

 

Adnan Zafar
Certified LabVIEW Architect
Coleman Technologies
0 Kudos
Message 2 of 6
(3,232 Views)

Labview mobile module 8.6. the PDA is operating Windows mobile 6. Yes I have installed NI-VISA ont he PDA.

 

I have tried as you suggested. I used the VISA find resource VI and found ASRL1::INSTR. I then fed this to the open VISA connection VI. I now get the same error code but the source is now VISA write.

 

 

0 Kudos
Message 3 of 6
(3,201 Views)

I have fixed the below as I should have used ASRL8::INSTR to my VISA open connection.

 

However when I run the application ont he pDA, it crashes without reason after a few iterations of the loop. I have attahced my code to see if anyone can shed some light on why?

0 Kudos
Message 4 of 6
(3,193 Views)

Hi jamie310382.

May I ask you how do you install NI-VISA on the PDA?

I ask because I try to install NI-VISA to smartphone (Samsung i607 - windows mobile 5)  but it failed

The error is "this installation file is not intended for this device."

I also try on another phone with WM 6.0 (same error)

Do I need to do anything before I can run installation?

Computer XP service pack3

Device Samsung, Q phone (WM 5.0or 6.0)

Activesync 4.5

Labview 8.6

NI-VISA 4.4 (I try all version 4.5; 4.6 same error)

Thank you for your help.

TP

               

0 Kudos
Message 5 of 6
(3,040 Views)

Jamie,

 

I had the same issue and I could not fix it.

Apparently VISA works fine on a PC and does not work properly on a PDA. I think this is one of those known issues reported by NI.

 

I fed a string COM8 into basic serial communication and it worked fine.

Watch out because the read and write to serial require visa so you have to be consistent.

 

Take care

0 Kudos
Message 6 of 6
(3,021 Views)