Want to use DSP module on LV 2010 to use Goertzel vi

I am using LV 2010

 

But I found a vi I want to use which is in the DSP module called the Goertzel vi.

 

But it seems when I try to install the DSP module whcih I downloaded from ni website it requires LV 8.6

 

Is there a way I can install DSP module on LV 2010 to use Goertzel vi?

0 Kudos
Message 1 of 2
(2,844 Views)

The DSP module is not compatible with LabVIEW 2010.  It looks like there are several options here.  You can install a parallel installation of LabVIEW 8.6 or 8.6.1 and then install the DSP module.  It also looks like the Goertzel algorithm has been added to the MathScript RT Module as shown in goertzel (MathScript RT Module Function)

Scott A
SSP Product Manager
National Instruments
0 Kudos
Message 2 of 2