Hey Gabi1,

What version of LabVIEW are you using? Can you post a vi, or give instuctions? I can't get the behavior you see using 8.2 or 8.5.

"Oh, to be thusly boned."


0 Kudos
Message 11 of 14
(1,016 Views)

occured on 8.2.1

copied a cluster control, to a subvi. this main vi has an oversized FP (for larger screen than my laptop)

in the subvi, pasted the control. moved it around to connect. checked on FP, and the bundled controls in the cluster have moved within its frame. some of them became completely invisible. did not investigate further.

cant reproduce this morning on an LV 8.2.0 . will check tonight at home.

-----------------------------------------------------------------------------------------------------
... And here's where I keep assorted lengths of wires...
0 Kudos
Message 12 of 14
(1,003 Views)
Hi everyone,
Thanks for posting this strange behavior.  It looks like a bug to me and I have filed a corrective action report ID: 4G98SSQ9 on it.  Please let me know if any of you need a workaround.  Thanks for bringing our attention to this issue and NI is now aware of it. 
Eric A.
National Instruments
Distributed I/O Product Support Engineer
Message 13 of 14
(983 Views)
Hi,
I am letting everyone know that the CAR ID is actually 4G994EQ9.  I apologize for any confusion and please let me know if I can help anyone with a work around.  Thanks to everyone for bringing this issue to our attention.
Eric A.
National Instruments
Distributed I/O Product Support Engineer
0 Kudos
Message 14 of 14
(910 Views)