LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Why does the express vi Write Labview Measurement File not allow me to use the comma delimiter.

I don't usually use the express vi's but I thought I would save a bit of time and try the Write Labview Measurement File. It looked OK but my file came out as Tab delimited, not comma as I selected. I set Comma for the delimiter but it always reverts to Tab.
 
Needless to say I've spent more time trying to figure out whats going on, than I would have done using my normal Write characters to file Smiley Sad
 
I must have missed something obvious, any ideas?
 
Ian
0 Kudos
Message 1 of 11
(4,212 Views)
This seems to be a bug in LabVIEW 7.1. Upgrade to LabVIEW 8.0 and it's fixed. 🙂
 
(Of course you could always convert the express VI to a plain VI and manually (right-click...open front panel) and set the diagram constant for the delimiter.)
Message 2 of 11
(4,203 Views)
Thanks altenbach
 
That's just what I need. I'll take the cheaper option for now and try out v8 when I get a bit more cash!!
 
Ian
0 Kudos
Message 3 of 11
(4,195 Views)

I'm using LabView 2012 and trying to use Write to Measurement File to save data in the lvm format. The problem is that I need to use the comma separation delimiter but I cannot access this option in the configuration. The only option available is the Tabulator. The Comma option is grayed out.

My vi worked just fine in LabView 8.5 but when I open it in 2012 version it forces the use of the Tabulator Delimiter.

Any ideas?

 

Nuno

0 Kudos
Message 4 of 11
(3,681 Views)

@NunoSilva wrote:

I'm using LabView 2012 and trying to use Write to Measurement File to save data in the lvm format. The problem is that I need to use the comma separation delimiter but I cannot access this option in the configuration. The only option available is the Tabulator. The Comma option is grayed out.

My vi worked just fine in LabView 8.5 but when I open it in 2012 version it forces the use of the Tabulator Delimiter.

Any ideas?

 

Nuno


The VI works fine for me.  Can you take a screen shot?  Maybe there's a combination of settings that is causing the disable of the option.

 


GCentral
There are only two ways to tell somebody thanks: Kudos and Marked Solutions
Unofficial Forum Rules and Guidelines
"Not that we are sufficient in ourselves to claim anything as coming from us, but our sufficiency is from God" - 2 Corinthians 3:5
0 Kudos
Message 5 of 11
(3,674 Views)

Could it be that your computer has a country setting that uses commas a decimal seperator?

In this case, using them also as column delimiters would create a real mess.

0 Kudos
Message 6 of 11
(3,666 Views)

It does not matter what configurations I choose. Comma delimiter is never available.

0 Kudos
Message 7 of 11
(3,650 Views)

You did not answer my question about your country setting.

0 Kudos
Message 8 of 11
(3,646 Views)

I'm not sure but I also thought about that being the reason.

 

But, shouldn't it be also unavailable in LabView 8.5?

0 Kudos
Message 9 of 11
(3,645 Views)

My country setting is Portuguese.

 

0 Kudos
Message 10 of 11
(3,642 Views)