12-16-2010 10:14 AM
Hi,
I'm a student in engeneering and need to do a work in labview. It's a Signal generator with in-built osciloscope.
The VI was working fine ultil I add the property nodes to change wavegraph scales and the VI start breaking with them.
Can anyone see my VI and tell me why does it happen?
I send the VI below.
Best regards
Ricardo Ferreira
Solved! Go to Solution.
12-16-2010 10:39 AM
The VI is not broken and can run.
However, your axes are set to auto scale so the property nodes for the axes and auto scale are constantly fighting each other.
12-16-2010 11:08 AM
Hi,
Thank you a lot for your time :)))) you've really helped me.
Best Regards
Ricardo