Write wsn-3202 shared variable name to channel name of measurement file

Solved!
Go to solution

I am using the output of multiple Shared Variable nodes, assigned to a WSN-3202 analog channels, as input into the Write To Measurement File Express VI. They are merged before going into the Write To Measurement File Express VI using the Merge Signals Function. I am writing the data to a text (VLM) file. In the output text file the the columns containing data from the WSN-3202 analog channels are titled "Untitled", "Untitled 1", "Untitled 2" and so on. I want these titles to be based on the WSN-3202 node name and channel they represent. How would this be done? I have attached the output text file.

0 Kudos
Message 1 of 6
(2,998 Views)
Solution
Accepted by topic author BJFUNCC

Hi,

 

There is a VI called Set Dynamic Data Attributes where you set your signal name. 

 

21860iEF10DB36FCAE4753

 

Hope this helps!

Tejinder Gill
National Instruments
Applications Engineer
Visit ni.com/gettingstarted for step-by-step help in setting up your system.
Message 2 of 6
(2,979 Views)

Thanks Tejinder, I was hoping for a simple solution like this!

0 Kudos
Message 3 of 6
(2,972 Views)

can you tell me how did you create the shared variable?

0 Kudos
Message 4 of 6
(2,746 Views)

Take the on-line LabVIEW Tutorials, or use the LabVIEW Help function.

0 Kudos
Message 5 of 6
(2,738 Views)

Hi kaoutar,

 

We recommend creating a new post for new questions, since this forum hasn’t been active for a while. To get started with shared variables, you can visit the next document:

Using the LabVIEW Shared Variable:

http://www.ni.com/white-paper/4679/en/

 

Regards,

AGJ

0 Kudos
Message 6 of 6
(2,710 Views)