05-13-2016 02:22 PM
Hi there guys. Can anyone tell me why my XY graph will not reset when my boolean button goes from false to true?
Solved! Go to Solution.
05-13-2016 02:58 PM
You mutiliated the express VI by opening the front panel and possibly making changes. Since the subVI is not attached, we cannot tell what's happening.
Please go back and use the stock express VI. Does it work better?
How many times does the "sweep" case execute? You seem to go to sweep case on the FALSE-TRUE condition, at which point the TRUE-FALSE transition does not occur and you immediately go to the stop case.
05-13-2016 03:20 PM - edited 05-13-2016 03:20 PM
Adding back the untouched VI fixed the problem, and you were right about the control selector. They were reversed for some reason. Thanks Altenbach!
05-13-2016 03:34 PM
Also note that the FALSE-TRUE condition first executes the init case, so once the sweep case comes around we no longer have that transition on the button and the graph will not initialize as you expect.