Yes I do actually want to acquire at 120MS/s ,i've just want to try this bloc ping-pong but i don't know how it works or how it is activated once i run my VI ,I'm just trying to find a solution for my problem .

0 Kudos
Message 11 of 16
(777 Views)

if you see the picture that i've joined before it's an .exe that i want to recreate there is a "scan clock source " at double internal ,this mode allowed to the data to be sampled at 120MS/s , Do you have any idea how can i do that ?

0 Kudos
Message 12 of 16
(776 Views)

Hi nasnas,

 

check the sources for that EXE. Or ask the one who created the EXE!

Or read the manual for your DAQ device to learn about its options. (Do you mind to attach the manual or provide a link?)

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 13 of 16
(775 Views)

I don't have any sources of that EXE.  . I searched in forums they said that there is no way to get it . And the EXE was created by Labo i've contacted them they said that they don't have sources available for publishing .

you can find the manual attached .

 

0 Kudos
Message 14 of 16
(765 Views)

Hi nasnas,

 

you attached the SpecSheet, but no manual.

That datasheet mentions some driver and SDK, also for LabVIEW. Get them from AdLink and create your own VI - after reading the manual…

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 15 of 16
(763 Views)

i've read about shift registers and I tried to do my acquisition with and without them but it gives me the same results . It's not the problem as it seems , and with the Chart it doesn't work also .any idea please of how it could be solved ? because after that i want to get the enveloppe of my data to get the t1,t2,t3,t4 .