The despiker uses an array of data as input. You do not need to build the table. You may modify it as necessary.

Lynn
0 Kudos
Message 21 of 23
(681 Views)
Dear Lynn,

Thanks for your reply. I could not manage to connect output of measurement data from HP to  array of data  from HP despiker program although I tried many times. According to the error report from Labview , it stated that I am connected to the output of subvi. I think array of data as input and interpolated data as output. How can I manage to modify in order to connect ?Please let me know your suggestions.

regards,
Toyota
0 Kudos
Message 22 of 23
(672 Views)
Toyota,

Please post your VI which has the problems. There is probably a simple explanation, but without the current version of the VI, it is very difficult to tell what is wrong.