LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

basic function generator problem

When I run the the basic function generator VI in version 6.0.2, and set the frequency (which context help tells me is in Hz), something strange happens... I run the generator for, say, 5 seconds at a frequency of 1 Hz, but instead of having an output of 5 peaks and troughs in my waveform (e.g. sine wave) I have thousands and the time elapsed as shown on the x-axis of my display cart is ~2 hours! Am I missing something really obvious? I've used this before and don't remember having the same problem. See attached .bmp.
0 Kudos
Message 1 of 2
(3,561 Views)
Don't forget to wire the "sampling info" input with the appropriate data. Default is 1000 pts at 1000 pts/s, at EACH run of the vi !

CC
Chilly Charly    (aka CC)
0 Kudos
Message 2 of 2
(3,556 Views)