02-04-2010 08:48 AM
Hello,
After installing labview 2009 my labview program cannot find 'DAQmx Create Channel(AO-Voltage-basic).vi'.
I have installed the newest NI Device Drivers CD but still no effect.
Before the NI Device Driver CD I uninstalled labview 8.6 and removed the folder in National instrument directory.
Can someone please tell me how to install the daqmx drivers for USB6009?
grtz,
Bart
02-04-2010 10:11 AM
02-05-2010 12:17 AM - edited 02-05-2010 12:21 AM
HEy,
Well all my daqmx for the usb-6009 are gone.
I know they are not drivers for the 6009 specific
Other Vi's where write.vi read.vi etc...
Can I not manually copy the files to its destination somehow.
NI-DAQmx Device Driver 9.0.2 is listed in MAX under the software tab.
gr.
02-05-2010 12:33 AM
btw,
The folder from NI consist of NI-DAQ, this folder contains some subfolders with llb but I can't open them.
They have to be linked somehow to labview I think.
gr
02-05-2010 01:56 AM - edited 02-05-2010 01:56 AM
Hi darkxceed,
Is your USB device working in the Measurement and Automation explorer?
You should have this folder:
C:\Program Files\National Instruments\LabVIEW 2009\vi.lib\DAQmx
If not, you can try a repair. Be sure that Labview 2009 support is enabled in the installer.
Regards,
Bas
02-05-2010 09:15 AM
Well I tried it all repair and such.
Now I have uninstalled complete NI software and installed all new, and now it works.
This costed me about 3 hours, could not do other things in meanwhile.
gr,