03-20-2008 12:27 PM
03-21-2008 01:28 PM
The USB-6008 allows only software-timed updates to its digital to analog converter (DAC), up to 150 samples per second, so a continuous analog output is “possible,” but it will be limited to slow update rates and the timing will not be as accurate as a card capable of hardware timed analog outputs.
For a LabVIEW example of software-timed analog output, please see the "Gen Mult Volt Updates-SW Timed.vi" example, available in the LabVIEW example finder (Help»Find Examples»Hardware Input and Output»DAQmx»Analog Generation»Voltage).
Another example can be found at the following link:
Continuous Software Timed Analog Output
for the USB-6008 and USB-6009
03-22-2008 02:42 AM