I've got LV 7.1 and 8.0 on my developement station, and I'm having trouble with a new station that I've loaded LV 8.2 on.

Both machines have a niDMM (4060) card, and the latest driver that I have in house (2.5.0), however the 8.2 LV installation doesn't "see" any DMM VI's.

MAX shows the card, and the software. The DMM Soft Front Panel is present and working, but if I search for "DMM" under VI search, none are found. And some code previously written can't find any DMM VIs so it won't load. Right clicking on the wiring diagram to bring up the measurement pallet shows no niDMM sub pallet on it.

What happened?

I"ve tried removingh and reinstalling the niDMM driver.

Any suggestions?


~~~~~~~~~~~~~~~~~~~~
Paul Johnson
Renco Encoders, Inc
Goleta, CA
~~~~~~~~~~~~~~~~~~~~
0 Kudos
Message 1 of 3
(2,626 Views)
Never mind.

I loaded DMM 2.5.1 from the LV 8.2 install disc and all is well Smiley Very Happy
~~~~~~~~~~~~~~~~~~~~
Paul Johnson
Renco Encoders, Inc
Goleta, CA
~~~~~~~~~~~~~~~~~~~~
0 Kudos
Message 2 of 3
(2,624 Views)

Glad to see you solved the problem Paul. 

For anyone else out there that might be encountering the same issue, support for LabVIEW 8.2 was introduced in NI-DMM version 2.5.1.  If you do not have the driver CD, you can download the latest dmm driver here.

Regards,

Jennifer O.
Applications Engineer
National Instruments

 
0 Kudos
Message 3 of 3
(2,609 Views)