Hi,
This is not a bug. We cannot change name labels at run-time. Changing control names requires recompile of the VI, and when a VI is reserved, we do not allow any operation that would cause the VI to be recompiled. The property node in this case returns error 1000, which indicates that the VI is not in the valid state for this operation.
http://digital.ni.com/public.nsf/websearch/FD0257A4429A26E886256992006ACC0F?OpenDocument
BUT, LabVIEW 8.0 seems to allow that change dynamically....
Regards,
David D.
Application Engineer - NI France
11-07-2005 02:40 AM
Hi David,
I am not sure this is not a bug since this VI works fine in LabVIEW 7.0 !
For your information, using unit allows changes interactively or programmatically at run-time within the same unit class (per example mm --> cm or in).
In the attached VI, if you don't retrieve property node, error 1000 doesn't appear.
Jean-Louis Schricke