error 1074388985

After reinstallation of Windows 2000 on my machine, and sequently reinstallation of LabVIEW 7.0, my VI that previously has beeen working well, now generates error-1074388985 probably in function "CAN Sync Start with NI-DAQ.vi" (function downloaded from this site from file nican22.exe). Does anybody know what's the matter and any solution?
0 Kudos
Message 1 of 4
(2,980 Views)
Andrea,
the error means that you are trying to set up signal routing when a CAN task has already been started.
When the SW previously worked on your machine, what version of NI-CAN were you running?
If it is not a big problem for you, would you mind attaching here a small piece of code that would allow us to reproduce the same exact error?

Regards,
AlessioD
National Instruments
0 Kudos
Message 2 of 4
(2,980 Views)
Ciao AlessioD!
Grazie per la risposta. Per motivi di riservatezza legati al contratto di supporto tra NI e il Centro Ricerche Fiat sono disponibile a inviarti il VI ma non a condividerlo sul forum. Potresti indicarmi un indirizzo a cui inviarlo?
Grazie
Andrea Volpi
0 Kudos
Message 3 of 4
(2,980 Views)
Andrea,
you should go to ni.com/ask and post an e-mail support request attaching your code. that will get in our inbox. It is the only way for you to send us an email since we do not know your email address.

Regards,
AlessioD
National Instruments
0 Kudos
Message 4 of 4
(2,980 Views)