09-26-2009 03:48 PM
I think you missed the actual problem, which is with TDMS files, not generic file reference.
When using a TDMS file reference, there doesn't seem to be any way to get the file path.
It is not a TDMS file property, can't seem to use a property node.
Even at TDMS Close, there is no path information returned, like there is with the 'regular' File Close.
It doesn't appear that NI has ever addressed this. Do you know if that is the case? Will you get back to us after you "consult your resources"?
09-26-2009 05:10 PM - edited 09-26-2009 05:12 PM
I'm not sure what the problem is but in LabVIEW 8.6.1 on my machine the Refnum to Path function simply returns the path to the file that TDMS refnum refers too. Is there anything more you want?
I'm talking here about the TDMS Open node and friends.
Rolf Kalbermatter
09-26-2009 08:29 PM - edited 09-26-2009 08:32 PM
Hah! and... DOH! Obvious in hindsight (why could I not think outside the tdms api? shameful) I missed the answer just previous so I apologize for the snarky reply.
Thanks for the good answer.
10-19-2009 12:46 PM
For future reference this does not appear to work on 8.5.1 - is there an acceptable work-around (perhaps with flattened variant)?
Jamie
10-19-2009 01:41 PM
8bitbanger wrote:For future reference this does not appear to work on 8.5.1 - is there an acceptable work-around (perhaps with flattened variant)?
Jamie
There need to be reasons to upgrade
10-19-2009 02:08 PM - edited 10-19-2009 02:13 PM
Hah! I would love to install 8.6.1 (sitting right here!), but NI dropped cFP-20xx support from RT after 8.5.1. Too many field devices deployed and I am leary about maintaining two installs.
PS - NI's official email response (truncated), no joke: "One work around is to upgrades to LabVIEW 2009".