 DutchEngineer
		
			DutchEngineer
		
		
		
		
		
		
		
		
	
			10-26-2022 05:08 AM
Hi LabView-guru's,
I would like some help regarding 
finding and debugging root cause error-message: "Hardware not detected". 
How to detect which hardware is missing? I use NI Max to detect faults in administered devices.
any help is most welcome,
Best regards,
LabView-novice
Solved! Go to Solution.
 GerdW
		
			GerdW
		
		
		 
		
		
		
		
		
	
			10-26-2022 06:43 AM - edited 10-26-2022 06:44 AM
Hi novice,
@DutchEngineer wrote:
finding and debugging root cause error-message: "Hardware not detected".
How to detect which hardware is missing? I use NI Max to detect faults in administered devices.
When the indicator "find list" is empty then there are no (VISA) devices available…
Where does that one-button-dialog comes from? Can you attach (real) code of the VI in your first image?
This code contains the information which hardware is needed to perform its operations…
Which (available) devices are shown in MAX?
10-26-2022 07:03 AM
 GerdW
		
			GerdW
		
		
		 
		
		
		
		
		
	
			10-26-2022 08:18 AM
 RTSLVU
		
			RTSLVU
		
		
		
		
		
		
		
		
	
			10-26-2022 11:33 AM
The problem with instruments on a Com port is:
I wou use VISA find resources to find every Com port then write some code to determine if the instrument is present and what Com port is is on.