how can i find the gain/amplification factor used when acquiring a voltage signal using PCI 6036E

in short, i am interested in find the sensor gain for used in feedback loop simulation
0 Kudos
Message 1 of 3
(2,850 Views)
If you are using traditional daq (not daqmx), the solution to your problem can be found in a KnowledgeBase at the following URL:

http://digital.ni.com/public.nsf/websearch/C93D3954EC02393C86256AFE00057BB0?OpenDocument

Basically, in the daq advanced sub-palette you can use the hardware config to retrieve the gain, just pass in the task id and nothing else and read the output cluster.
0 Kudos
Message 2 of 3
(2,850 Views)
Greetings!

The gain setting defaults to unity gain, but it is selectable to x10 or x100, also. (This is your pre-digitizing gain, of course...after it's in digital form, you can tweak the gain to anything you want in your VI.

Hope this helps.

Eric
Eric P. Nichols
P.O. Box 56235
North Pole, AK 99705
0 Kudos
Message 3 of 3