I believe it has something to do with DAQmx base. On the first computer I have all the hardware attached and working. Computer 2 does not have any of the hardware the program is controlling and does not have mx base. I'm using the USB-9211x (whatever the correct pn is, it requires mx base) thermocouple interface and it requires DAQmx base. When going to NI website to find mx base there are a dozen options of things to download but none of them seem correct so I have to check with computer 1 in the morning and see what I installed for mx base. I also use DAQmx (without the base) for a different USB i/o device (6008), so both DAQ software is necessary.
If I search for "libsseries.dll" on computer2 I find "libsseries.dll.DAQMXB" so I'm not sure it is a problem with DAQmxbase except that MAX does not show mxBase installed. Control panel shows DAQmx 8.5 installed and also no mxbase so I don't know what libsseries.dll.DAQMXB is.
gtb
07-03-2007
12:25 PM
- last edited on
06-25-2025
09:13 AM
by
Content Cleaner
I believe that the version of DAQmx base that you will need will be the version for Windows located here:
http://digital.ni.com/softlib.nsf/websearch/1C9142D75EFD398F862572970050C3C9?opendocument&node=132060_US
07-03-2007 04:33 PM
Yes, that is the version I found on computer 1, fortunately with the already downloaded zip file. It did the job. Thanks to all for their response.