Hi,

I have a small application that continously displays an image acquired via the Vision Development Module, and NI-IMAQ for USB (all in latest version, LabView 7 Express). It runs fine locally. When I try this application in the integrated web server however, the "Display Image" control remains black.

Any help would be appreciated!

Regards
Matthias
0 Kudos
Message 1 of 4
(2,797 Views)
Do you have the IMAQ drivers installed on the remote machine?

Prakash K
0 Kudos
Message 2 of 4
(2,791 Views)
Hi,

no, I don't. I supposed that it should run on any remote machine... Do I really have to?!?

Matthias
0 Kudos
Message 3 of 4
(2,783 Views)
Yes. You will have to install it if you are displaying the image using the image display control.

There are ways to get around this though - using a intensity graph or picture control. Try the following link for more information:

http://digital.ni.com/public.nsf/websearch/B6258C0AE767659D86256F3900578F6A?OpenDocument

Prakash K
0 Kudos
Message 4 of 4