LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

vizualised both signal and filtered signal on the same graph

Solved!
Go to solution

Hi,

I want to perform an online filtering of an eeg signal acquired with an external device. This is an initial draft (not for an online measurement, yet) of the future vi because I want to be sure for now that the filtering is working. However, the result does not appear. More precisely I cannot view the two signals at once. The sampling frequency is 256Hz and the filter used is Butterworth, passband, 1-20Hz. I do not know where is the mistake, although I search a few days in the forum after an answer. I please for help.

0 Kudos
Message 1 of 3
(2,097 Views)
Solution
Accepted by AncD

Works as expected:

check.png

Even when (or: because of) not using ExpressVIs and DDT wires…

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 2 of 3
(2,083 Views)

Many thanks for suggestion and approachability.

 
 
0 Kudos
Message 3 of 3