09-16-2010 07:46 AM
Dear all,
I have a problem when using the "Writing to Measurement File. vi" in Labview. I'm using this vi to save data from a physical channel, in a tdm file format. Afterwards, I would like to generate a report of this recorded data with DIAdem.
In DIAdem, is there any possibility to directly see this recorded data as a waveform channel instead of a numeric channel?
Morevoer, when using DIAdem, the data saved can be seen in different time interval groups defined as untitled 1, untitled 2...I would like to have all the recorded data in only one of those untitled groups.
I would really appreciate that somebody could help me,
Thank you very much,
Miren
09-29-2010 02:24 AM
Hi Miren,
I would suggest using theVIs in the "TDMS Streaming" palette instead of using "Write to Measurement File" Express VI. You may find interesting some of the examples included in LabVIEW, specially "Write Channel Groups (TDMS)". You can check this examples on Help >> Find Examples >> Searh for TDM.
Hope this helps,