LabWindows/CVI

cancel
Showing results for 
Search instead for 
Did you mean: 

-89130 Device not available for routing.

Hello  (message en français plus bas)

I have a problem on a machine that I am trying to make,here is a description of

the machine:

I have a motor which drives a trolley in translation via a belt,the trolley is connected to an optical rule.

I whent to acquire an analog signal in same time that the points of the optical rule and when I starting the motor.

hardware PCI 6323

 

I have the following tasks

An edge counter task (continuous acquisition clock type external  clock sources ai / StartTriger rising edge.

My analog acquisition task it is triggered on PFI0.

 

BUT  when I start my task in my code via DAQmxStartTask I have the following error message:

 

-89130 [0xfffea3d6]). Device not available for routing.
The device may need to be reset or the device may be in the process of resetting.
If you reset the device, wait for the reset to complete.

For example, if you used the device via traditional NI-DAQ,you must reset the device before the requested route can be completed.

 

I tried to do a reset, reinstalled NIMAX but no results.

 

I use exactly the same code and the same tasks on 12 identical machines

the only changes on this machine is Windows 10 64bits and on the other machin works on Windows 7 32bits or XP

 

Anyway, I'm really running out of ideas to solve my problem, if your have idea you'r welcome

 

FRANCAIS:

Bonjour

 

je rencontre un problème sur une machine que je suis en train de faire, voici un bref descriptif de la machine

j'ai un moteur qui entraine un chariot en translation via un courroie, le chariot est reliée à une règle optique.

je souhaite acquérir un signal analogique en concordance avec les points de la règle optique et au démarrage de mon moteur.

niveau hardware j'ai une PCIe 6323

 

pour ça j'ai les taches suivantes

une tache compteur de front (acquisition continue, type d'horloge: externe,  sources d'horloge : ai/StartTriger front montant.

ma tache d'acquisition analogique elle est déclenchée sur PFI0 .

 

MAIS car il y a un mais, au moment même ou je start ma tache dans mon code via DAQmxStartTask j'ai le mesage d'erreur suivant:

 -89130 [0xfffea3d6]). Device not available for routing.

It is possible that the device needs to be reset or that the device is being reset.

 If you are resetting the device, wait for the reset to complete.

 For example, if you have used the device through Traditional NI-DAQ, you must reset the device before the requested route can be made.

 

j'ai essayer de faire un reset, réinstallé NIMAX mais aucun résultat.

 

j'utilise exactement le même code et les mêmes taches sur une dizaine de machines identiques, la seul chose qui change sur cette machine c'est Windows 10 64bits et sur les autres machine qui fonctionne Windows 7 32bits ou même XP 

 

bref je suis vraiment à cours d'idées pour solutionner mon problème, si quelqu'un à une piste ...

 

 

 

 

  

0 Kudos
Message 1 of 2
(2,010 Views)

hello

 

today y have remplace the pcie6323 by 2 pci6221 => same result

0 Kudos
Message 2 of 2